HORIBA Worldwide

  • Home
  • Company Profile
  • Employment
  • Investors
  • Contact Us
  • Request Info
  • Products
  • Markets & Industries
  • News & Events
  • Scientific References
  • HORIBA Scientific Segment
  • International
    Links
Applications
Measurement Types
Product List
Location: Products >> Fluorescence >> Lifetime >> Fluorolog-TCSPC
FluoroLog®-TCSPC - TCSPC on your FluoroLog® Spectrofluorometer
Time-Correlated Single-Photon Counting on the World's Most Sensitive Spectrofluorometer

Fluorolog-TCSPCWe start with the best steady-state optical bench from HORIBA Jobin Yvon SPEX®, add in a pulsed laser-diode or a pulsed spark source, and finish with a superior detector-module.

The Result?

The World's Most Sensitive Spectrofluorometer, with TCSPC ready to perform time-domain lifetime spectroscopy! You get the reliability and know-how of the SPEX® FluoroLog® series, together with the solid-state economy and sensitivity of IBH lifetime analysis, all in one instrument. All functions are software controlled from a host computer, giving you access to data with just a few keystrokes. A high repetition rate light source rapidly builds up a histogram of the sample's fluorescence decay.

So why use TCSPC for time-resolved experiments?

  • Variations of the excitation beam's intensity are irrelevant
  • Detects individual photons
  • No pulse-smearing from boxcar gates
  • High speed data-acquisitions
  • Digial precision, and no analog offset required for fitting results
  • The entire decay curve is examined at once

Of all the modern time-domain methods, including boxcar integration and streak cameras, TCSPC has by far the best dynamic range. If your sample lifetimes are really important, then SPEX®-IBH TCSPC is the method for you.

Technical Specifications

Exciation Sources 
Steady-State
Broadband 450-W Xenon arc lamp from UV to near-IR
TCSPC
  • Fixed-wavelength "Plug and Play" interchangeable NanoLED pulsed laser-diodes and LEDs. Wavelengths of 280, 340, 375, 405, 440, 473, 635, 650, 785 and 830 nm are available for laser-diodes. 370,455, 465, 485, 560, 590, 605, 625 for LEDs. Standard optical pulse durations are <200 ps (<100ps typical) for laser-diodes, <1.5 ns for LEDs.
  • 5000F coaxial nanosecond flashlamp with broadband output from 180-780 nm.
    Thyratron-gated spark and pulse generator (10 Hz - 100 kHz). Minimum optical pulse-width is 0.6 ns.
 
Spectrometers 
Czerny-Turner, with classically-rulled gratings and all reflective optics. Optional double-grating spectrometers available. For standard 1200-grooves/mm.
Resolution
0.2 nm
Accuracy
± 0.5 nm
Speed
150 nm/s
Range
0 - 1300 nm
 
Detectors 
TCSPC and Steady State
TBX photomultiplier tube module, response 185 - 650 nm. Dark counts < 80 cps (< 20 cps typical). Timing jitter typically 180 ps FWHM, 250 ps maximum. Optioncal cooled extended-red detectors are available to 850 nm.
 
Lifetimes Measureable 
TCSPC
< 100 ps to 100 µs lifetimes
MCS
< 10 µs to seconds (depending on source)
 
Software 
Runs under Windows™

Brochure












  • Privacy Policy